Replacing wood shakes in Thousand Oaks: does the deck change?
Often, yes. The code lets wood shakes sit on spaced boards with gaps between them, but it puts asphalt shingles, clay and concrete tile and slate on a continuous deck of plywood-type panels or tightly laid boards, so a shake roof laid on spaced boards generally needs a solid deck before the new covering goes on.
That deck is real labor and material, so it should be written into the scope from the first bid. When you ask for Roofing H Thousand Oaks roof replacement on a shake house, ask the roofer to check what sits under the shakes and to list the deck as its own line item.
Why were shakes laid on spaced boards?
Section R905.8.1 of the California Residential Code lets wood shakes go on panels, on solid boards or on spaced boards. Spaced boards have a minimum nominal size and sit on centers that match the shake exposure, so each row of nails lands on wood. Section R803.1 points spaced sheathing back to those rules.
Where shakes on spaced boards are open to the attic, the code wants that attic ventilated and bars backing materials that fill the required air gap. The result is a deck made of strips with open space between them, not a continuous surface.
Which new coverings need a solid deck?
Each covering has its own sheathing rule in Chapter 9. Section R905.2.1 says asphalt shingles get nailed into panel sheathing or solid board sheathing, nothing with gaps. Section R905.6.1 sets the same rule for slate.
Section R905.3.1 puts clay and concrete tile over the same kinds of deck, with an exception for spaced sheathing only in the lower seismic design categories.
Before counting on that tile exception, ask the roofer or the City’s Building Division which seismic design category applies to the house. The answer decides whether tile can use the existing boards at all.
Metal is the partial exception. Section R905.4.1 asks for panels, solid boards or closely fitted boards under metal roof shingles unless the product is designed for spaced sheathing, and Section R905.10.1 lists spaced lumber sheathing among the accepted decks for metal roof panels. The product literature decides which case applies.
Does the old roof come off down to the boards?
For a replacement, yes. Under Section R908.3, a replacement strips every layer of old covering until the deck is bare. On a shake house, the tear-off is when the spaced boards, their condition and any rot come into view, so the bid should say how damaged boards or rafters found then will be handled.
A solid deck also changes how the attic breathes. Air that moved through the gaps between the boards now stops at the new panels, so the attic’s own vents, which the ventilation rules in Chapter 8 govern, deserve a look in the same bid.
What does Thousand Oaks add?
Inside city limits, the City’s Municipal Code requires Class A fire-rated roofs, so whatever replaces the shakes must carry that rating as a tested product or assembly. Lynn Ranch, Casa Conejo and Westlake Village lie outside Thousand Oaks city limits, so confirm the fire class required for the parcel with the agency that issues the permit there.
Keep the document that shows the rating with the permit papers, since it is the proof if anyone asks later.
- What sits under the shakes now: spaced boards, solid boards or panels.
- Whether new panels go over the spaced boards or the boards come out.
- The panel type and thickness proposed for the new deck.
- How rotten boards or damaged rafters found at tear-off will be priced.
- The new covering, its fire class and its underlayment.
- Whether the attic vents change once the gaps between boards are closed.
Short answers
Can asphalt shingles go on spaced boards?
The code says no: Section R905.2.1 wants panel sheathing or tight solid boards beneath every asphalt shingle.
Does tile need a solid deck too?
Generally, yes. Section R905.3.1 keeps spaced boards under tile to the three lowest seismic design categories.
Is metal any different?
Sometimes. Metal panels may go on spaced sheathing, and metal shingles may too when the product is designed for it.
Roofing H Thousand Oaks handles roof replacement for houses and commercial buildings, along with repair, new installation and maintenance, in Thousand Oaks, Westlake Village, Casa Conejo, Lynn Ranch and Newbury Park, backed by 34 years of roofing experience. If shakes are coming off your house, dial 805-227-8617 and ask us to check the boards underneath first.
Next in this series: Must a Thousand Oaks HOA put its new roof decision in writing?.